Lennox 33F37 Flame Sensor Canada
GS11 sensor G8 sensor G11 sensor
FOR EMERGENCY DELIVERY PLEASE CALL 1-844-737-2787
Replaces 33F3701, 26F17, 26F170128C27, 28C2701, 73A59, 73A5901.
Used with Models G11E-200 6, G11Q3E-137V 8, G11Q4E-137V 8, G12D2E-55 6, G12E-137 6, G12E-137 8, G12E-82 6, G12Q3E-137 6, G12Q3E-137 8, G12Q3E-82 6, G12Q5E-137 8, G12RD2E-55 8, G12RQ3E-82 6, G8-105E ,1 G8-105E 2, G8-105E 5, G8-120E 5, G8-150 1, G8-150E 1, G8-150E 2, G8-150E 3, G8-180E 1, G8-180E 2, G8-180E 5, G81E-65-82 1, G8-210E 5, G8-90E 1, G8R-105E 1, G8R-120E 2, G8R-120E 3, G8R-150E 1, G8R-150E 2, G8R-150E 3, GF8-105 3, GF8-105E 3, GF8-120E 3, GF8-90 3, GF8-90E 3, GS11D2E-80 0, GS11D2E-80 2, GS11DE-60 3, GS11DE-60 4, GS11DE-60 5, GS11DE-80 0, GS11DE-80 2, GS11DE-80 3, GS11DE-80 4, GS11DE-80 5, GS11E-60 0, GS11E-60 1, GS11E-60 2, GS11E-60 3, GS11E-60 4, GS11E-60 5, GS11E-80 5, GS11Q3E-140 0, GS11Q3E-140 2, GS11Q3E-140 3, GS11Q3E-140 4, GS11Q3E-140 5, GS11Q3E-60 0, GS11Q3E-60 2, GS11Q3E-60 3, GS11Q3E-60 4, GS11Q3E-60 5, GS11Q3E-80 0, GS11Q3E-80 2, GS11Q3E-80 3, GS11Q4E-120 0, GS11Q4E-60 1, GS11Q4E-60 4, GS11Q5E-120 5, GS11Q5E-140 0, GS11Q5E-140 2, GS11Q5E-140 3, GS11Q5E-140 4, GS11Q5E-140 ,5 GS11Q5E-160 0, GS11Q5E-160 2, GS11Q5E-160 3, GS11Q5E-160 4, GS11Q5E-80 0, GS11Q5E-80 1, GS11Q5E-80 4, LF3E-110 1, LF3E-220 1, LF3E-275 1, LF3E-330 1
Product Specifications:
The flame sensor is a device located at the burner assembly and can be found in furnaces, boilers and other gas-burning appliances.
The purpose of the flame sensor is to confirm that whenever the gas valve is open, a fire or flame is present. If there were nothing to ignite, once gas is emitted, a dangerous build-up might occur. Flame sensors have a short time in which to detect a flame. If no flame is detected, the unit will automatically shut down. If this shutdown happens after a few times, a safety lockout usually happens that shuts the unit down for more than an hour. In the case of carbon build-up on a dirty flame sensor, a furnace will keep shutting down - a common complaint by homeowners. Carbon build-up is often caused by dusty particles in the air that burn to a sensor, especially if the furnace is located in areas that typically collect a lot of dust, such as basements and attics.
Flame sensors can be cleaned by using emery cloth and steel wool.
HeatingPartsCanada carries a wide selection of flame sensors.
Not finding the part you are looking for, or need help cross-referencing?
Give our friendly staff a call at 1-844-81-PARTS.